5-3. Transmitter Frequency Test
a. Test Equipment Required
(1) Frequency Meter AN/USM-207.
(2) Comparator, Frequency CM-77A/USM.
b. Test Connections and Conditions. Connect the equipment as shown in figure 5-1. Connect A4TP5 to ground.
--
c. Procedure.
Control settings
Test
Performance
Equipment under
test
Step
Test equipment
procedure
standard
AN/USM-207
1
a. Turn on the AN/USM-207 and CM-
MODE: 1
a. None.
DIRECT/HETRODYNE
FUNCTION: SYSTEM.
77A/USM. Permit a l-hour warmup.
Switch: HETRODYNE
CODE: Any.
b. Turn on the test set, and permit a 2-
b. None.
VOLTAGE Switch: 10V
POWER 115 vac or 28 vdc, as
minute warmup.
FREQ TUNING-MC: 150
c. None.
c. Press the PRESS-TO-TEST switch and
applicable.
POWER TRACK
turn to LOCK.
FUNCTION: FREQ
SENSITIVITY: Plug in
CM-77A/USM
a. None.
2
FREQUENCY MEGACYCLES: 206.
MEGACYCLES
and
VIDEO
VIDEO RESEONSE-GAIN: CW.
R E S P O N S E c o n t r o l s until
the
RESPONSE-HIGH
VIDEO
oscilloscope display indicates zero
FREQUENCY: CCW.
beating (setting should be near 206).
b. 1,030 mc 206 kc.
b. Note the frequency on the AN/USM-207
add 150 to it and multiply the results
by 5.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |