Click here to make tpub.com your Home Page

Page Title: Transmitter Frequency Test
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

a. Test Equipment Required
(1) Frequency Meter AN/USM-207.
(2) Comparator, Frequency CM-77A/USM.
b. Test Connections and Conditions. Connect the equipment as shown in figure 5-1. Connect A4TP5 to ground.
--
c. Procedure.
Control settings
Test
Performance
Equipment under
test
Step
Test equipment
procedure
standard
AN/USM-207
1
a. Turn on the AN/USM-207 and CM-
MODE: 1
a. None.
DIRECT/HETRODYNE
FUNCTION: SYSTEM.
77A/USM. Permit a l-hour warmup.
Switch: HETRODYNE
CODE: Any.
b. Turn on the test set, and permit a 2-
b. None.
VOLTAGE Switch: 10V
POWER 115 vac or 28 vdc, as
minute warmup.
FREQ TUNING-MC: 150
c. None.
c. Press the PRESS-TO-TEST switch and
applicable.
POWER TRACK
turn to LOCK.
FUNCTION: FREQ
SENSITIVITY: Plug in
CM-77A/USM
a. Adjust the CM-77A/USM FREQUENCY
a. None.
2
FREQUENCY MEGACYCLES: 206.
MEGACYCLES
and
VIDEO
VIDEO RESEONSE-GAIN: CW.
R E S P O N S E c o n t r o l s  until
the
RESPONSE-HIGH
VIDEO
oscilloscope display indicates zero
FREQUENCY: CCW.
beating (setting should be near 206).
b. 1,030 mc 206 kc.
b. Note the frequency on the AN/USM-207
add 150 to it and multiply the results
by 5.

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business