Normal
Control
Settings
Paragraph
Procedure
Test eguipment
test
reference
Step
P2 should be 2
to measure the spacing between the
sec 0.2. Delay
P1, P2, and P3 pulses.
between P1 and P2
should be sec
0.2.
d. Set the test set MODE switch at each of d. P1-P2 pulse spacing.
the following positions and measure
delays.
Mode (1) 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(1) 5 sec
0.2
(2) 8 sec
(2) 3/A . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0.2.
(3) 21 sec
(3) C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0.2.
(4) 6.5 sec
(4) TEST . . . . . . . . . . . . . . . . . . . . . . . . . .
0.2.
a. Connect the equipment as shown in a. None.
MODE: 2
9
AN/UPM-98
CODE (A, B, C, D):
CODE (A, B, C, D): 7777
figure 3-5. Connect oscilloscope
7777
FUNCTION: N
CHANNEL A to A8TP2.
PRESS TO TEST:
AMPLITUDE: 2
CAUTION
SUB PULSE SELECT OFF
Be sure that the TS-656/U Power
POWER: 115V
LEVEL: LO
Supply voltage adjustment se at 0
PULSE WIDTH: 0.45
output or damage to the diodes in
......................
WXTAL MARK & SYNC UNIT:
the MD-796 will result.
SYNC SELECT? -EXT.
SUP: Completely CCW
POWER ON
Trigger Delay 5-50
b. Connect the output of the AN/URM-64 b. None.
AN/URM-64
to the rf input of the MD-796 and the
POWER ON
output of the MD-796 to the probe
Signal Frequency: 1065 MC
input to the transponder test set.
Attenuator: Fully Clockwise
c. Be sure the voltage adjustment on the C. NOne.
AN/USM-281A
TS-656 is fully counterclockwise. Turn
Same as step 7
the POWER switch to ON and adjust
the voltage to 0.8 Be sure the
negative lead is connected to the center
conductor of cable.
d. Press and turn the PRESS TO TEST d. None.
TS-656
knob to the position. The accept
POWER OFF
light should be on. If it is not, adjust
Voltage: OFF
Function: DC Volts
the AN/URM-64 Frequency knob until
the transponder test set indcates
steady accept. Then adjust the
|