![]() TM 11-6625-3017-14
TABLE 5.2
Test Equipment Required for Realignment
Item
Type
Minimum specification
Recommended model
a
Range: 0 - 20 V d. c.
Hewlett-Packard
0 - 270 V a. c.
HP410A
b
Variable mains
Range: 190 - 260 or
General Radio
90 - 160 V a. c.
Model W1OMT3A
c
Wave analyser
Range: 50 - 200 Hz
Hewlett-Packard
Sensitivity: 50 V
HP 302A
d
Differential
Discrimination: 1 mV in 18 V
Fluke
Model 881AB
e
Frequency meter
Range: f*
Hewlett-Packard HP 5245L
with HP 5261A
f
R. F.
Range: f*
Hewlett-Packard
millivoltmeter
HP 3406
g
T connector
BNC-BNC-BNC
h
Crystals
Frequencies: 22, 23 and 44 MHz
i
Response
4 to 1000 MHz
Rhode & Schwarz
analyser
'Polyskop' SWOB II
j
Signal source
Range: 100 Hz - 23 kHz
TF 2001 with
standardized attenuator
k
Sensitive
Range: 100 Hz - 23 kHz with
Hewlett-Packard
dB calibration
HP 427A
l
Crystal oscillator
Frequency: 1.5 MHz
0.014 LF
m
Capacitor
n
R. M. S. voltmeter
Frequency: 30 Hz - 150 kHz
Hewlett-Packard
Sensitivity: 1 mV full-scale
HP 3400A
o
Sensitivity: 10 mV/cm
Hewlett-Packard
HP 1700B
f*;
range to suit user's requirements within coverage of TF 2300
(4 to 1000 MHz).
5-4
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |