T. O. 12P4-2APX-192
NAVAIR 16-35TS1843-1
TM 11-6625-1646-25
NOTE
4. Perform interrogation level alignment as follows:
An intermittent GO, NO GO may be
a. Place transponder test set test set AN/APM-362
displayed on the transponder test set test
controls in the following positions:
set AN/APM362 when adjusting AlAAS5C5
OPERATE/STANDBY - STANDBY
(01A23375021-11 only) and AlAlA5C6 at the
TS1843( )/APX POWER AND CONTROL -OFF
*3 MHz points.
When an intermittent
PRF SELECT - 80%
condition is encountered, alignment should
BEAT FREQUENCY SELECT - OFF
be repeated until the GO indicator is on
VIDEO GAIN ADJUST - INC
steady.
MODE SELECT - 2
d. Adjust AlAlA5C5 (01A233750-21-11 only) and
b. Make test connections per figure 9-10. Connect
AAlA5C6 for maximum pulse amplitude display on
oscilloscope probe to transponder test set test set AN/APM-
oscilloscope.
362 connector J5.
e. Move transponder test set testsetAN/APM-362
c. Move transponder test set testsetAN/APM-362
TS1843( )/APX POWER AND CONTROL switch to OFF.
TS1843( )/APX POWER AND CONTROL switch ON. Adjust
Disconnect alignment connections; alignment is complete.
VIDEO GAIN ADJUST control for oscilloscope display of two
pulses spaced five microseconds apart with an amplitude of 1
volt (approximate).
9-22
|