T. O. 12P4-2APX-192
NAVAIR 16-35TS1843-1
TM 11-6625-1646-25
Table 9-3. Adjustment
STEP
NO.
SWITCH POSITION
PROCEDURE
INDICATION
ADJUSTMENT
NOTE
Unless noted otherwise all switches
and indicaters are located on the
Transponder Test Set Test Set,
AN/APM-362.
1
REPLY FREQUENCY SELECT
Make test connections per figure 9-3.
MHZ - 1090
BRACKET SPACING SELECT
MICROSECONDS - 20.30
PRF SELECT - STDBY
INTERROGATION LEVEL - -65
BEAT FREQUENCY
SELECT - OFF
OPERATE/STANDBY- STANDBY
ON/OFF - OFF
TS-1843( )/APX LINE
VOLTAGE SELECT - 28
MODE C CIRCUIT TEST - OFF
MODE SELECT - OFF
POWER - OFF
2
INPUT POWER CONNECTOR
POWER ON (2) and STANDBY
SELECT (located on rear of chassis) - J1
indicators light.
ON/OFF - ON
POWER - ON
TEST SET CURRENT meter indicates
MODE SELECT - MONITOR
270 ma.
PRF SELECT - 400
OPERATE/STANDBY - OPFRATE
3
BRACKET SPACING SELECT
GO indicator lights for
If GO indicator does
MICROSECONDS - All positions
each switch position.
not light for each
except 20. 07 ALIGN POS.
switch position adjust
TS-1843A/APX A4C6.
4
BRACKET SPACING SELECT
GO indicator lights.
If GO indicator does
MICROSECONDS - 20.07
not light adjust TS-
ALIGN POS.
1843A/APX A4C6 until
GO indicator lights.
9-19
|