T.O. 12P4-2APX-192
NAVAIR 16-35TS1843-1
TM 11-6625-1646-25
Table 9-2. Troubleshooting (Continued)
STEP
CIRCUIT
AN/APM-362
TEST
TEST
NORMAL
IF INDICATION
FUNCTION
CONTROLS
POINT
EQUIPMENT
INDICATION
IS ABNORMAL
9
TIME
A2A9-8
Waveform 22.
Replace A2A9.
ENABLE
GATES
A2A8-6
Waveform 23.
Replace A2A8.
A2AU-8
Waveform 23.
Replace A2A8.
10
REFERENCE
A2A9-5
Waveform 24.
Replace A2A10.
ENABLE
GATE
SYNC
A2A3-3
Waveform 25.
Replace A2A3.
ENABLE
GATE
A2A2-10
Oscilloscope
Waveform 25,
Replace A2A2.
inverted.
A2TPI
Waveform 15.
Replace A2A3.
MODE 1
A2A9-4
4.3 to 4.9 V.
Replace A2A2.
GATE
A2A9-5
Waveform 24,
Replace A2A9.
inverted.
MODE 2
MODE SELECT
A2A1-9
4. 3 to 4. 9 V.
Replace A2A2.
GATE
2
A2A1-8
Waveform 26.
Replace A2All.
MODE 3/A
MODE SELECT
A2AI-9
4. 3 to 4. 9 V.
Replace A2A2.
GATE
3/A
A2A1-8
Waveform 27.
Replace A2A1.
MODE C
MODE SELECT
A2A1-5
4. 3 to 4. 9 V.
Replace A2A2.
GATE
C
MODE C
A2A11-6
Waveform 28.
Replace A2A11.
CIRCUIT
TEST - ON
9-14
|