CONDITION
PROBABLE TROUBLE
CORRECTION
31 l 1V for 2 hours. The charge should be com-
plete and the switch should reset at least once
during the second hour of charge, otherwise
replace battery.
With battery at a temperature of 400F or less,
No capacity after low
Inoperative heater.
use ohmmeter and measure resistance between
temperature charge.
Pins A and C of connector MS3112E-14-5S.
Reading should be 10 +1 ohm. A reading of 20
ohms would indicate that one of the two heater
blankets are defective. Only the top heater is
replaceable. An open reading would indicate a
defective thermal switch. Replace thermal
switch or use battery only at temperatures
above 300F.
Loosen eight screws holding the control module
Overheating on
Shorted bypass diode.
plate to battery. Diode is located under 6 pin
charge
connector. Check with TS-352B/U in ohmmeter
mode. A low resistance in both directions would
indicate a defective diode. Replace diode if
shorted.