TM 11-6140-224-13&P
Table 4-2.
Organizational Troubleshooting Chart Continued
CONDITION
PROBABLE TROUBLE
CORRECTION
No capacity before battery cutoff.
Battery not charged.
Charge battery at 30 volts.
Defective pressure switch control preven-
Higher category of maintenance repair re-
ting charge.
quired.
Battery charged at low temperature with
Check resistance of heater through Pins A and C
inoperative heater.
of MS3112E-14-5S connector. At temperatures
below 50 +50F resistance is 10 ohms above 50
50F read open circuit. If other values are
measured, higher category of maintenance
repair required.
NOTE
If no source of charging power is
available. the latch relay may be reset, in
an emergency. by using a short length of
wire (or paper clip) to quickly short the
back of socket 1 (white/red wire) to socket
3 (red wire) on the internal 3 pin connector.
After relay clicks "on" remove the shor-
ting wire.
4-8
|