CONNECTOR UG-1870A/U REPLACEMENT (CONT)
29. Install split ferrule (1) into middle body (2).
30. Pull slightly on cable.
Twisting cable 360 makes inner cables come together. This, in turn, allows split ferrule
(1) to seat better in middle body (2).
31. Twist cable 360.
NOTE
Copperweld braid and cable fillers (3) should extend over edge of middle body (2) when
tape is removed.
32. Remove tape from combed out copperweld braid and splayed cable fillers (3).