TM 11-5995-208-24&P-1
CONNECTOR UG-1870A/U REPLACEMENT (CONT)
8. Trim coaxial braid (4)3/8 1/32 of an inch from coaxial jacket.
9. Wrap braid with masking tape.
10. Trim coaxial dielectric (5) 13/16 1/32 of an inch from coaxial braid, leaving coaxial
--
center conductor (6) exposed 11/64 1/64 of an inch.
11. Using 60/40 solder, tin two coaxial cable center conductors (7).
3-7
|