EQUIPMENT PERFORMANCE DATA (CONT)
Characteristic Impedance:
55 to 62 ohms in the frequency range of 500 kHz to 20 MHz.
temperature is.66F; 2 ohms for 100 feet of cable when temperature is 68F.
68F; 0.9 ohms for 100 feet of cable when temperature is 68F.
2 db for each 1320 feet (1/4 mile) of cable at 20 kHz; 9.5 db at 2300 kHz; 32.0
Signal Attenuation:
db at 20.0 MHz.
Tensile Strength of Cable: 1200 pounds.
Tensile Strength of Junction between Cable and Connector: 350 pounds.
Span and Minimum Sag Specifications: