EQUIPMENT PERFORMANCE DATA (CONT)
Characteristic Impedance:
55 to 62 ohms in the frequency range of 500 kHz to 20 MHz.
DC Resistance of Center Conductor:  22 ohms for each 1320 feet (1/4 mile) of cable when
temperature is.66F; 2 ohms for 100 feet of cable when temperature is 68F.
D  C Resistance of the Shield: 7.5 ohms for each 1320 feet (1/4 mile) of cable when temperature is
68F; 0.9 ohms for 100 feet of cable when temperature is 68F.
2 db for each 1320 feet (1/4 mile) of cable at 20 kHz; 9.5 db at 2300 kHz; 32.0
Signal Attenuation:
db at 20.0 MHz.
Tensile Strength of Cable: 1200 pounds.
Tensile Strength of Junction between Cable and Connector: 350 pounds.
Span and Minimum Sag Specifications:
WARNING
Be sure you know what the minimum clearance is before you hang your cable. Your
supervisor or team chief should give you specific clearance heights before you start out
on your cable laying mission.
Do not put cable connectors in the span.