TM 11-5995-208-10
EQUIPMENT CHARACTERISTICS, CAPABILITIES, AND FEATURES (CONT)
TWIN COAX ADAPTER CABLE (CX-10734/G)
Overall length is 4 feet.
Contains the same type small coaxial cables as twin coax cable
assembly.
Used to connect twin coax cable assemblies to MUX equipment, early
model unattended repeaters, attended repeaters, or old type signal
entrance boxes.
UNATTENDED REPEATER (TD-206(*)/G)
Must be used after every mile of twin coax cable assembly to boost the
PCM signals.
Must be at least 1/2 mile of twin coax cable assembly between the un-
attended repeater and the MUX equipment.
After 40 miles of twin coax cable and unattended repeaters, an attended
repeater must be connected.
The early model unattended repeater (TD-206/G) needs a twin coax
adapter cable to allow its connection to twin coax cable assembly.
1-6
|