TM 11-5920-252-24
4.
Perform short circuit test as follows:
Set TS-352B/U FUNCTION switch to OHMS and set range switch to RX 10000
Connect one lead of the TS-352B/U to ground. At the J connector connect the other TS-352B/U lead to
each pin of the faulty channel. All resistance measurements should be more than 1 megohm
(1,000,000 ohms). Reverse the TS-352BIU leads and repeat the resistance measurements. All
measurements, again, should be more than 1 megohm. If any measurement is less than 1 megohm,
higher level of maintenance is required.
TABLE 2.2. CONTINUITY CHART
Channel No.
Connectors
Connector pins
1
J1-P1
A
B
C
D
2
J
K
L
M
3
E
F
G
H
4
N
P
R
S
5
J2-P2
A
B
C
D
6
J
K
L
M
7
E
F
G
H
8
N
P
R
S
9
J3P3
A
B
C
D
10
J'
K
L
M
11
E
F
G
H
12
N
P
R
S
2-6
|