TM 11-5820-489-20
TO 31R4-2GRA6-32
CAUTION
Do not use steel wool. Particles can enter the case and cause
harmful internal shorting or grounding of circuits.
C. Marking.
q Marking of electrical and electronic parts shall be in accordance with MIL-STD 1285A.
2-15. FINAL INSPECTION PROCEDURES
The final inspection procedures make sure that all maintenance functions contained in this
manual have been complied with before the equipment has been returned to service.
A. Modifications.
q Be sure that any MWO's listed in DA PAM 310-1 have been performed,
B. PMCS.
q Be sure that all PMCS in Section lll have been performed.
C. Completeness.
q
Inspect the Control Group for completeness. Refer to TM 11-5820-489-20P for a listing of
components and accessories.
q
Check to make sure that each item is correctly stock numbered.
q
Be sure that the correct quantity is in the package.
D. Final Performance Check.
q The components of the Control Group shall meet the requirements of Section V before
operating, packaging, or storage. if operation checks, PMCS, or a final performance
check cannot be satisfactorily performed, contact the next higher level of maintenance.
Section Vi. PREPARATION FOR STORAGE AND SHIPMENT
2-16. DISASSEMBLY OF EQUIPMENT
Use the procedure below when placing AN/GRA-6 in storage or moving it to a different Iota
tion.
A. Disconnecting Cables.
Remote Control C-433/GRC.
q Remove Interconnecting Box plug from AUDIO connector on front panel.
q Remove handset if it is attached directly to AUDIO connector on front panel.
2-16
|