Controls/Indicators
Function
TEST CONTROL group (Cont)
DISPLAY RESET switch
When pressed, extinguishes all lighted
indicators except POWER CONTROL ON
indicator.
FAULT LOCATION group
MULTIPLEXER CARD indicator
Lights when a multiplexer card malfunction
is detected. Remains lighted until reset.
MULTIPLEXER OUT OF TOL indicator
Lights when an out-of-tolerance condition
is detected on one or more input channels.
DEMULTIPLEXER CARD indicator
Lights when a demultiplexer card malfunction
is detected. Remains lighted until reset.
FAULT LOCATION numerical display
Functions are as follows:
a) When MULTIPLEXER CARD or DEMULTIPLEXER CARD
indicator  is  lighted,  displays  numerical  location  of
malfunctioning card.
b) When MULTIPLEXER OUT OF TOL indicator is lighted,
displays number of channel that is out of tolerance. When
two or more channels are out of tolerate at the same time,
displays number of these channels sequentially.
c) When SELF TEST switch is in on (up) position and no
malfunction exists, displays 00. When SELF TEST switch is
in on (up) position and a malfunction exists, displays
numerical location of card whose diagnostic circuits are
malfunctioning.