T.O. 31W2-2GSC24-2
TM 11-5805-688-14-1
NAVELEX 0967-LP-545-3010
Table 1-3. Electrical Capabilities and Limitations (Cont)
Parameter
Capability
Type II - digital data without
Data rates up to 9600 bps, which have
associated timing (timing
a data sense transition (1 to 0 or
recovery processing technique)
0 to 1) at least once each 100 data
bit times and fitting the expression:
R = 75 x 2n bps
c
where:
n = integer from 0 to 7
Voice
300 to 3400 Hz, using a sample rate
(KRp) equal to or greater than 19.2
kbps. Slower sample rates may be
used with a corresponding decrease
in performance parameters.
Channel rate variation
Type I
+250 parts per million (ppm)
Type II
+250 ppm. Channel input rates, including
rate variation, being processed
by the transition encoding technique
cannot exceed 400 bps.
Voice
Not applicable
Channel input levels
Types I and II
+0.5v minimum (logical 1) and -0.5v
minimum (logical 0)
Voice
-16 dBm at 1000 Hz for full modulation
Channel output levels
Types I and II
Positive and negative 6+1 volts, open
circuit
Voice
+7 dBm at 1000 Hz with fully modulated
channel input