e. All leaks, including thin areas of the coat ing
4-23.
Inflation test of the hood will be as follows:
detected during inflation shall be returned for repair.
a. Inflate the hood to a pressure of 2 to 4 inches(water
NOTE
column) with oil free and water free air.
For determining pressure in coveralls, manometer or
magnehelic gage, FSN 6685-526-8629 or FSN 6685-
b. The oil-free and water-free air shall be introduced
087-6331 may be utilized.
into the hood through the oral inflation valve and tube.
4-21A. Alternate Leak Test.
Following procedures
c. The air supply shall be securely shut off. Immerse
outlined in paragraphs 4-21a, b, and c, introduce and
a portion of hood in water and check for leaks. Continue
maintain a minimum of 1/8 PSI pressure inside the
procedure until entire hood has been checked for leaks,
coverall. Apply a soap and water solution to the seams
or use a soap and water solution to detect leaks.
and cemented areas and observe for bubbles which are
evidence of leakage.
d. The air will be discharged through the oral inflation
4-22.  After  inflation  test  the  cove rall  shall  be
assembly upon completion of test.
thoroughly dried, dusted lightly with talc, and folded and
positioned in carrying case (refer to Figures 3-1 and 3-
Change 20 4-9/(4-10 blank)