(16) Operating pressure on gage is between 6 and 20 psi.
If pressure on gage reads between 20-25 psi, turn flame down to about one-half
size, and continue operation for 1/2 hour. If pressure increases, beyond 25 psig,
turn unit off, remove from cabinet, and allow to cool before placing back in op-
eration.
NOTE
Safety valve device is installed to prevent pressure buildup over 60 psig, will bleed off
into the mixing chamber.
2-7.
STOPPING THE EQUIPMENT.
Do not release the fuel tank air pressure while the unit is lit, while smoking or
near an open flame.
Remove the flame valve knob from the holder and place on the generator valve stem. Turn the knob clockwise until
a.
tight. Remove flame valve knob and replace in holder. Allow cabinet and burner unit to cool.
If necessary to remove an unlit hot burner unit from the cabinet to an outside cooling area, use a two person carry. Wear
b.
heat protective gloves.
2-8.
DISMANTLING FOR MOVEMENT.
If the unit is to be moved from the immediate vicinity, provide adequate cushioning material for loose components
a.
and accessories inside the cabinet.
Allow components such as pots, pans, griddle, etc. to cool before stowing them in
the field range cabinet.
b.
Stow all components and accessories in their proper containers. and stow components and containers in the field range
cabinet. Secure cabinet door.