SB 740-95-20
APPENDIX C
TRC-LSR
QUALITY ASSURANCE INSPECTION INSTRUCTIONS
License
WARNING
Name
NSN
(See C-4a)
The shelf-life items cited in the inspection
Level. Fire Control
1290-00-257-2769
2
instruction contain radioactive sources.
Light Assembly
1290-00-257-2773
2
Inspection shall be performed in a well
Quadrant. Fire Con-
1290-01-037-7289
2
ventilated area.
Precautions relative to
trol
Light, Assembly
1290-01-043-8209
2
handling radioactive material are as defined
Alignment Device,
2
in applicable license(s) issued by the US
Optic
Nuclear Regulatory Commission (NRC).
Dial Control
2
Light, Source, Potted
6060-01-048-0694
2
Lamp, Radioluminous
2
C-1. Purpose.
The purpose of this inspection
Lamp, Radioluminous
6260-01-053-3355
2
instruction is to provide necessary information and
Index, Potted
2
procedures for inspection of armament materiel
Lamp, Radioluminous
2
containing radioactive material.
C-4. Inspection Procedures.
C-2. Policy. These inspection instructions have been
a. General.
Inspection, in addition to that
designed to detect any significant deterioration of
prescribed in APPENDIX A and this inspection
material in storage and to avoid over-inspection.
instruction, shall comply with AR 700-64 Radioactive
Commodities in the DOD Supply Systems (DSAM
C-3. Inspection.
For purposes of this inspection
4145.8), and the applicable license(s) (listed below)
instruction, material is identified as indicated below:
issued by the US Nuclear Regulatory Commission
(NRC).
License
US NRC LA 12-00722-04
M16A1 Radioactive Rifle Sight
Name
NSN
(See C-4a)
US NRC LA 12-00722-06
Radioluminous Devices (H-3)
Sight Kit. Low Light
1005-00-071-8030
1
Infantry and Towed Artillery
Post Assembly, Front
1005-00-145-6378
1
US NRC LA 12-00722-07
Light
Anti-Tank
Weapon
Post Assembly. Front
1005-00-234-1568
1
Radioactive
Front
Sight
Scale, Indicating
1010-01-053-3353
2
Promethium-147
Telescope, Panoramic
1240-00-150-8886
2
US NRC LA 12-00722-09
Tritium Illumination for Muzzle
Telescope, Elbow
1240-00-150-8889
2
Reference Sensor (M68 Family of
Mount, Telescope
1240-00-150-8890
2
Cannons)
Cell Assembly, Optic
1240-00-257-2759
2
b.
Inspection Condition.
Sphere. Potted
1240-00-257-2770
2
(1) Inspection lot. An inspection lot is defined
Light Source, Potted
1240-00-257-2771
2
Light Assembly
1240-00-257-2774
2
as all items having the same level of packaging and year
Light Assembly
1240-00-257-2776
2
of manufacture, rebuild, or modification.
Modification Kit
1240-00-332-1779
2
Collimator, Infinity
1240-00-322-1780
2
shall be as prescribed in appendix B.
Lamp Radioluminous
1240-00-332-1783
2
Mount, Telescope
1240-01-039-7273
2
(3) Inspection lot disposition criteria.
Objective and Reticle
1240-01-043-9463
2
(a) Accept lot. Accept in accordance with d
Assembly
below.
Mount, Telescope
1240-01-050-5588
2
(b) Reject lot. Reject in accordance with d
Telescope, Elbow
1240-01-051-3657
2
Lamp Unit,
1240-01-051-8472
2
below.
Radioluminous
c. Defect Classification.
Scale, Indicating
1240-01-053-3354
2
(1) Failure of any one of the applicable
Level, Fire Control
1240-01-057-0112
2
functional or visual inspection, or tests specified below in
Cell Assembly, Optic
1240-01-079-3032
2
Cell Assembly, Optic
1240-01-079-5453
2
this inspection instruction shall be considered a major
Quadrant, Fire Con-
1290-00-150-8891
2
defect.
trol
(2) In addition, visual inspection defect classi-
Light Aiming Post
1290-00-169-1934
2
Light Aiming Post
1290-00-169-1935
2
Quadrant, Fire Con-
1290-00-169-1937
2
trol
Level, Fire Control
1290-00-257-2765
2
C-1
|