SB 740-91-01
Step
Setting and Instructions
Normal Indication
3.
(con't)
(a)
through all character locations.
The cursor consists of a rectangular
NOTE
array of dots, 7 wide by 9 high.
Verify that no more than 2 cells in
If It is necessary to carefully
any one cursor fail to properly
examine pixels, press any key
illuminate, erase or sustain. Also
to stop the cursor. Press it
verify that no more than 13 cells
a second time to restart.
will imporperly operate at all
cursor locations. Spacer-related
cells are excluded from this
criterion.
(b) Rotate DISPL BRT Control
Verify that the display brightness
can be adjusted in 6 steps, with
increasing brightness as the control
is turned clockwise.
(c) Press UPNL TEST" then "EXEC"
Menu will be displayed.
key.
4 Memory Test
Address Contents Test Number Running
(a) Press "E" key
Will be displayed on plasma panel.
Results of this test are evaluated
automatically therefore Running
will be replaced with Complete or
Repeat. Observe MEM I or MEM 2 or
2 BIT indicators in the event an
uncorrectable error occurs. These
indicators shall not illuminate, and
an indication of "Complete" shall be
obatained.
(b) Press "PNL TEST"
Menu is displayed.
5. Processor Test
Address Contents Test Numbers Running
(a) Press "F" key.
Will be displayed on plasma panel.
This test is automatically executed
and evaluated to verify execution or
each CPU instruction. When the test
is completed Running will be replaced
by Complete or Repeat. An indication
of complete shall be obtained.
Change 1 B-130.5
|