SB 740-91-01
10. SSS-013-003-3 Power Cable
a. Materials Required.
(1)
Cable, CC14UO-22P, 3.5 feet
(2)
Terminal lugs MS-25036-53, 4 each.
b. Construction.
(1)
Mark cable SSS-013-003-3 Power Cable
(2)
Mark either end of red wire positive "+"
(3)
Mark either end of black wire negative
(4)
Strip each end of wire 0.1875 inch. Securely crimp a terminal lug to each
stripped end of wire.
Diagrams. Not applicable.
c.
11. SSS-013-003-4 Test Cable No. 2.
a. Materials Required. This cable is identical to SSS-013-003-2 Test Cable No.
1 except as follows:
(1)
Connector plug MWIOM(M)D17, 18 pin 5835-00-815-2325 instead of U-344/VRC
(2)
All wire No. 14 AWG, terminal lugs MS-25036-49, 18 each
(3)
No terminal lugs MS-25036-53 required.
b. Construction. Same as SSS-013-003-2 (paragraph 9.b), except for marking of cable and requirement for the
two jumper wires. Mark this cable SSS-013-003-4 Test Cable No. 2.
c. Diagrams. Use those for SSS-013-003-2 (paragraph 9.c), except different connector.
12. SSS-013-003-5 Test Cable No. 3.
a. Materials Required.
(1)
U-229/U connector, 5 pin, 1 each
(2)
Terminal board, plastic, type PBE, 0.25 x 2.5 x 3 inches
(3)
Nut MS-85649-286, 10 each
(4)
Washer MS-15795-907, 5 each
(5)
Screw, Type I, Style 8s, brass 8-32UNC-28 x 0.75 inches long, 5 each
(6)
Terminal lug MS-25036-53, 5 each
(7)
Sleeving AWG, size No. 5
(8)
Twine, type P, class 2, waxed
(9)
Wire, No. 14 AWG, approximately 3 feet of different colors.
b. Construction.
(1)
Mark cable SSS-013-OOpOO003-5 Test Cable No. 3
(2)
Mark terminal letters on terminal board
(3)
For terminal board construction see paragraph 9.c. Make for 5 terminals
instead of 18
(4)
Overall construction is similar to that stated in paragraph 9.b
B-28
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |