Click here to make tpub.com your Home Page

Page Title: Procedural Steps:
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-3835-222-BD
Procedural Steps:
a. Remove the tube with adjustable wrenches.
b. Using a pen and a ruler, draw a straight line on the tubing, starting in the undamaged area,
through to the damaged section, into the other undamaged area.
c. Refer to the illustrations below to determine the repair method required.
d. Make one or two cuts as necessary to enable removal of the damaged section. If the distance
between the two cuts is less than 0.30 inches, use a repair similiar to the illustration below.
If the distance between the two cuts is greater than 0.30 inches, use a repair similar to the figure below.
e. Ends of tubing to be permaswaged must be centered inside the permaswage fitting. Use the
permaswage marking tool and the centering/marking instructions supplied with the permaswage kit.
Use the marking method below only if the marking tool is not available.
(1)
Mark half of the overall length of the permaswage fitting on the tubing end.
8-13