Page Title: Hose improvisation (Low Pressure)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-3835-222-BD
Procedural Steps:
a. Gain access to hose.
b. Drain coolant.
c. Loosen and remove clamp from one end of the hose.
d. Insert a can with ends removed or bent wire into the hose.
e. Reconnect and tighten the hose.
f. Refill coolant to proper level.
g. Check for leaks.
Record the BDAR action taken. When the mission is completed, as soon as practicable, repair the
equipment using standard maintenance procedures.
6-13. Hose improvisation (Low Pressure):  Coolant hose or tube damage will sometimes be such
that a patch will not stop the leak The damaged portion must be removed and replaced with a
substitute. Several repairs can be made using one of the following procedures.
Personnel/Time Required:
1 soldier - 15 minutes - 1 hr.
Materials/Tools:
Hose, Garden Or Hose, Heater
Pipe
Clamps Or Wire
Hacksaw
Gasket Sealer (Hardener) (appendix C, section II, Item 14)