5.4. MOTOR, ELECTRIC (MODEL 12681-7)
LOCATION/ITEM
ACTION
REMARKS
DISASSEMBLY
2. Continued
b. Remove two screws (4), box (5) and
gasket (6).
c.
Remove two screws (7) cover (8) and un-
solder capacitor leads to remove
capacitor (9).
d. Remove four nuts (10) and four bolts
(11).
e. Remove rear end plate (12) and front
end plate (13).
f.
Remove rear end bearing (14) and front
end bearing (15).
g. Remove switch (16) and rotor (17), from
stator and housing (18).
WARNING
Dry cleaning solvent, P-D-680 or P-S-661, used to clean parts is potentially
dangerous to personnel and property. Use in a well-ventilated area as the
fumes are dangerous if inhaled.  Avoid repeated and prolonged skin
contact. Do not use near open flame or excessive heat. Flash point of
solvent is 100F. - 138F. (38C. - 59C.).
CLEANING
3.
a
Clean end plates (12, 13) in an approved
cleaning solvent, and dry with a clean
cloth or compressed air.
b. Clean electrical parts with a clean soft
bristled brush or blow with compressed
air.
5-12