2-6. GENERAL OPERATING PROCEDURES Continued
d. Monitor the weight of service cylinder when the service cylinder is filled to the desired weight and shutdown the
recharging unit.
(1)
Press STOP pushbutton on starter control box.
(2)
Close valve on service cylinder and supply
cylinder.
(3)
Close discharge shutoff valve.
WARNING
Use care to protect your flesh from
contact with Carbon Dioxide (C02).  It
produces an effect similar to a scald or
burn. Stay clear of the inlet bleed valve
outlet port and the discharge blow-off
valve outlet port.
(4)
Slowly open (crack) the discharge blowoff valve
and the inlet bleed valve.
(5)
Disconnect hose from service cylinder.
2-10