TM 5-3610-254-14
6-9. SUPPLY STORAGE CABINET MAINTENANCE INSTRUCTIONS (cont)
LOCATION
ITEM
ACTION
REMARKS
REMOVAL (cont)
4. Water
a. Vacuum pump
Remove per paragraph 4-30.
Supply
Cabinet
b. Water tank
Remove per paragraph 5-13.
assembly
c. Sink drain
Remove per paragraph 6-11.
5. Sink Faucet
a. Plumbing
Disconnect.
b. Rivets (1)
Remove by drilling or
chiseling off heads.
c. Faucet (2)
Remove.
6. Bench
a. Cabinet drawers
Remove.
Removed for
Assembly
(3)
access to
mounting hardware.
b. Bolts (4), flat
Remove.
Remove exterior
washers (5), lock-
backing plates,
washers (6),
secured by
backing plate (7),
weatherproof
and nuts (8)
adhesive, if
necessary.
WARNING
Serious injury could result if heavy equipment is moved/lifted without sufficient personnel. Use a suitable
lifting device/dolly if possible or have sufficient personnel available for the task to prevent injury to personnel.
CAUTION
To prevent damage to other equipment, use care when removing the bench assembly because of the close
proximity of other shelter components.
c. Bench assembly
Slide from wall and
remove from shelter.
6-8
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |