TM 5-3610-254-14
5-28. MAIN POWER RECEPTACLE MAINTENANCE INSTRUCTIONS (cont)
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION
7. Recessed
a. Data plate (power
Position on recessed
Receptacle
requirements)
box, match drill holes,
Box
and secure with rivets.
b. Recessed box (12)
Position in shelter wall
Seal to shelter
opening and secure with
wall with RTV
rivets (11).
(item 3, app
E).
8. Main power
a. Receptacle (8),
Install.
Receptacle
cap (10), and
gasket
b. Screws (7), flat
Install.
washers (6), lock-
washers (5), and
nuts (4)
9. Main Power
a. Four main
Connect to terminals and
Install wiring
electrical wires
receptacle. Refer to
clamps as
wiring diagram in -
necessary.
para graph 6-17 for
proper connection.
b. Door and cover
Position on service box
Refer to
assembly
and secure with
attaching screws.
10. Rear of
Receptacle access
Position on receptacle
Receptacle
plate (1)
box (2) and secure with
Box
attaching screws (3).