3-32 ROTARY SWITCH (ALARM TEST) (CONT).
b.
Installation.
Position key (6) to align with hole and seat rotary switch (3) in panel assembly (7).
(1)
(2)
Secure rotary switch (3) with nut (4) and Iockwasher (5).
Install knob (2).
(3)
(4)
Tighten two setscrews (1).
Rotate knob (2) counterclockwise until it stops.
(5)
Loosen setscrews and set knob to position #4.
(6)
(7)
Tighten both setscrews (1).
Using FO-2 as a guide, connect five wires to rotary switch (3).
(8)
Install panel assembly and lid (para 3-11c steps 4 thru 8 and 20).
(9)