LOCATION
ITEM
ACTION
Housing Unit
Main fan/
5. Install rubber bushing (21) in slot in face of
housing unit (15) with slit away from housing.
dust collector
6. Aline guide pin hole (21) with guide pin (22).
Push dust collector against housing unit.
7. Install washers (13) and screws (12).
8. Install inlet transition (7) onto dust
collector (11).
9. Tighten hose clamps (8) on exhaust sleeve (9).
10. Tighten hose clamp (10) on inlet transition (7).
11. Compress airduct hose (5) until it can be
inserted between inlet collar (6) and inlet
transition (7).
12. Slip airduct hose (5) over inlet collar (6) and
inlet transition (7), and tighten hose clamps (4).
13. Connect electrical cable plug P4 (2) to power
distribution unit (3).
2-113