ACTION
LOCATION
ITEM
1. Set POWER switch on compartment control
Gas-Particulate
Inlet airduct hose
Filter Unit
module (1) to OFF.
2. Loosen two hose clamps (2) at top and bottom
of airduct hose (3).
3. Compress airduct hose (3) until it can be
slipped off the inlet collar (4).
4. Pull airduct hose (3) off inlet transition (5).
1. Push airduct hose (3) onto inlet transition (5).
2. Compress airduct hose (3) until it can be
slipped onto inlet collar (4).
3. Tighten two hose clamps (2) on airduct
hose (3).
4. Set POWER switch on compartment control
module (1) to ON.