2-15. M87 GAS-PARTICULATE FILTER UNIT (CONT).
ACTION
ITEM
LOCATION
1.
Filter unit stand
Set POWER switch (1) on compartment control
Gas-Particulate
module to OFF.
Filter Unit
Shut off power source.
2.
Remove power distribution unit (p. 2-95).
3.
Remove M5 static frequency converter
4.
Remove exhaust sleeve (p. 2-101).
5.
Remove inlet cap (p. 2-103).
6.
Remove inlet airduct hose (p. 2-105).
7.
Remove inlet collar (p. 2-100).
8.
Remove screws (1 and 3) and washers (2 and
9.
4), and remove reinforcing rod (5). Repeat for
reinforcing rod on other side.
10. Remove screws (6 and 7) and washers (8 and
9), and remove reinforcing rod (10). Repeat on
other side.
11. Remove eight screws (11) and eight
washers (12).
12. Remove two screws (13), washers (14), and
nuts (15) on sides of upper half of rear filter
unit stand (16).
13. Lift upper half of rear filter unit stand (16) off
of housing unit (17).
14. Remove front filter unit stand (18).
15. Remove lower half of rear filter unit stand (19).
2-98