ACTION
LOCATION
ITEM
Red tubing
1. Push red tube coupling nuts (6 and 8) with
Housing  Unit/Power
sleeves on red tube (10). See detail A.
(nonmetallic)
Distribution  Unit
2. Push one end of tube (10) into connector (7)
and one end into connector (9). RED dot on
power distribution unit indicates connector (9).
3. Push red tube coupling nut (6) with sleeve
onto connector (7) and hand tighten.
4. Push red tube coupling nut (8) with sleeve
onto connector (9) and hand tighten.
Push green tube coupling nuts (1 and 3) with
5.
Green tubing
sleeves on green tube (5). See detail A.
(nonmetallic)
Push one end of green tube (5) into connector
6.
(2) and one end into connector (4). GREEN dot
on power distribution unit indicates
connector (4).
7.
Push green tube coupling nut (1) with sleeve
onto connector (2) and hand tighten.
8.
Push green tube coupling nut (3) with sleeve
onto connector (4) and hand tighten.
2-97