NOTE
Perform checks and services in the order listed before you perform functional testing
Table 2-1. Preventive Maintenance Checks and Services (PMCS) Semiannual Schedule
Item
Procedures
No.
Item to be Inspected
1
M87 Gas-Particulate
Filter Unit
Housing Unit
Inspect instruction plates. You must be able to read them. Replace plates if
necessary (p. 2-107).
Inspect outside surfaces for rust, chipped paint, or bare metal on painted surfaces.
Repaint or touch up as necessary (p. 2-106).
Make sure that all parts are secure and that there is no loose or missing hardware.
Tighten loose hardware. Replace missing hardware.
Main fan assembly
Inspect cable assembly for bare wires, broken insulation, or broken connector.
Replace damaged main fan assembly (p. 2-111).
cable
Inspect unit for loose or missing mounting hardware. Tighten loose hardware.
Compartment
control module
Replace missing hardware.
Inspect warning plate. Warning plate must be legible. Replace plate if necessary.
Inspect unit for loose or missing mounting hardware. Tighten loose hardware.
Power distribution
unit
Replace missing hardware.
Inspect for damaged or missing electrical covers. Replace power distribution unit
if the covers are damaged or missing (p. 2-95).
WARNING
Gas-particulate
falters
DO NOT throw away damaged or unusable filters
a s ordinary trash.
D O turn in damaged or unusable filters to
y o u r hazardous waste management office or
D e f e n s e Reutilization and Marketing Office
(DRMO).
Remove falters (p. 2-91 and p. 2-92) and check for physical or water damage.
Inspect housing seal and inner cover seal for cracks, rips, hardening, etc. Replace
seal if damaged (p. 2-93). Reinstall falters or install new falters (p. 2-91 and
Airflow valve
Inspect valve for damage and loose mounting hardware. Replace missing
mounting hardware. Replace damaged airflow valve (p. 2-119).
M 10 Protective
2
Inspect instruction plates. Instruction plates must be legible. Replace plate if
Entrance
necessary (p. 2-80).
Inspect outside surface for chipped paint or bare metal on painted surfaces.
Repaint or touch up as necessary (p. 2-73).
Make sure that all parts are secure and that there is no loose or missing hardware.
Tighten loose hardware (p. 2-83). Replace missing hardware.
Change 1
2-2