2-15. COMPARTMENT CONTROL MODULE - MAINTENANCE INSTRUCTIONS (Cont),
LOCATION
ITEM
ACTION
REMOVAL
1. Disassemble CCM (p 2-171).
2. Remove wire leads from INDICATORS circuit
breaker (1).
3. Unscrew and remove waterproof boot (2).
4. Remove circuit breaker (1) and keying washer (3).
INSTALLATION
1. Insert INDICATORS circuit breaker(1) with keying
washer (3) in panel (4) and secure with waterproof
boot (2).
2. Connect wire leads. Refer to page 2-104.
3. Reassemble CCM (p 2-171).
REMOVAL
1. Disassemble CCM (p 2-171).
2. Remove wire leads from ENTRANCE PRESSURE
circuit breaker (1).
3. Unscrew and remove waterproof boot (2).
4. Remove circuit breaker (1) and keying washer (3).
INSTALLATION
1. Insert ENTRANCE PRESSURE circuit breaker (1)
with keying washer (3) in panel (4) and secure with
waterproof boot (2).
2. Connect wire leads. Refer to page 2-184.
3. Reassemble CCM (p 2-171).