INSTALLATION (CONT)
M56 Gas-Particulate Filter
Main fan/inlet tee
Install bushing (12) on cable ( 17) about 10 inches from
unit
motor.
Position inlet tee (10) up to filter housing (11).
Install bushing (12) in slot in face of filter housing (11)
with slit away from housing.
Aline guide pin hole (18) with guide pin (19). Push inlet
tee against filter housing.
Install washers (9) and screws (8). Tighten securely.
Connect electrical cable plug P4 (6) to power distribu-
tion panel connector J4 (7).
Connect electrical cable plug P15 (5) to airflow valve.
Install airduct hoses (3 and 4).
Tighten hose damp adjusting screws (2).
2-81