OPERATING POWER REQUIREMENTS AND CHARACTERISTICS OF COLLECTIVE PROTECTION
EQUIPMENT COMPONENTS
.
Maximum
Input
Power
Airflow (cfm)
Capacity
Voltage
Requirements
Component
28Vdc
2 amp at
Protective Entrance
28Vdc
Control Module
200 maximum
M56 Gas-Particulate
200 V,
800 Watts
Filter Unit
400 Hz,
3-phase
40 minimum
1 amp max
Airflow Valve
at 20.0 in.
at 28 V dc
water gage
3.5 kW
208 V,
Power Distribution
400 Hz,
Unit
3-phase
28 V dc
1 amp max
Compartment
at 28 V dc
Control Module
200
Particulate Filter
200
Gas Filter
1-7