2-152
TM 3-4230-209-30&P
2-33. LIQUID FUEL WATER HEATER AND CABINET TOP COVER (CONT).
LOCATION/lTEM
REMARKS
ACTION
DISASSEMBLY (CONT)
Liquid Fuel Water Heater and
Cabinet Top Cover/
Remove three machine screws (40),
Machine screws (40)
internal tooth lock washers (41), three
Internal tooth lock
hexagon plain nuts (42), and internal
washers (41)
tooth lock washers (43) from studs
Hexagon plain nuts (42)
located on boiler unit (28).
Internal tooth lock
washers (43)
Lift the wire bundle up away from
Access cover (44)
Nonmetallic grommet (45)
access cover (44) and make sure non-
metallic grommet (45) comes out of the
U-slot of access cover. Carefully guide
access cover (44) out from front of the
boiler unit (28).
Slip nonmetallic grommet (45) from wire
bundle and capillary tubes carefully.
Remove four hexagon plain nuts (46),
Hexagon plain nuts (46)
internal tooth lock washers (47), and
Internal tooth lock
machine screws (48).
washers (47)
Machine screws (48)
Lift access cover (49) out of the cabinet
Access cover (49)
frame. Remove electrical box
Electrical box
connector (50) only if damaged. Cut and
connector (50)
discard all electrical tiedown straps (51)
Electrical tiedown
on wire bundle over boiler unit (28).
straps (51)