TM 3-1040-220-34&P
20 Nipple
Legend for fig. 2-1:
21 Pipe tee
1 Metal tube assembly
22 Pipe fitting seal (with teflon insert)
2 Adapter
23 Pressure regulator
3 Pipe fitting seal (with teflon insert)
24 Bushing
4 Hose clamp
25 Elbow
5 Pipe fitting seal (with teflon insert)
26 Pipe fitting seal (with teflon insert)
6 Nipple
27 Nonmetallic hose assembly
7 Pipe fitting seal (with teflon insert)
28 Pipe reducer
8 Compressed gas cylinder
29 Dial indicating pressure gage
9 Compressed gas cylinder
30 Pipe fitting seal (with teflon insert)
10 Dead soft copper gasket
31 Metal tube assembly
11 Rupture disk
32 Adapter
12 Safety plug
33 Pipe tee
13 Elbow
34 Pipe plug
14 Nipple
35 Connector block
15 Pipe plug
36. Angle valve (charging valve)
16 Connector block
37 Quick disconnect coupling half
17 Nipple
18 Globe valve (High pressure control)
19 Pipe to pipe extension fitting
(d) Remove the adapter (2) from the cylinder (9).
2-2. Compressed Gas Cylinders
(e) Use a screwdriver and remove two hose clamps
a.
Description and Function.
The disperser is
(4) that fasten the cylinder (9) to the pressure group
equipped with two compressed gas cylinders (8 and 9,
support section. Remove the cylinder (9).
operation of the disperser. Each cylinder is a high-
(f) Disconnect the metal tube assembly (31) flare nut
tensile-strength cylindrical steel container mounted on
from the adapter (32). Using a wrench, remove the
the pressure group support section and secured by two
adapter (32) from connector block (35).
removable band-type hose clamps (4).
(g) Using a screw driver, remove the hose clamps
b.
Maintenance.
Direct support maintenance
(4) that fasten the cylinder (8) to the pressure group
personnel are authorized to replace the compressed gas
support section.
cylinders.
(h) Remove the cylinder (8), connector block (35),
(1) Removal.
and angle valve (36) as a unit from the pressure group
support section. Remove the connector block (35),
WARNING
angle valve (36), and adapter (6) from the cylinder (8).
Handle charged compressed gas
(2) Installation.
cylinders carefully damage to the
cylinders could result in an explosion.
(a) Coat all threaded connections with pipe
sealing compound (table 1-1).
(a) Close the globe valve (18) that is the high
pressure control.
(b) Installation of both cylinders (8 and 9) is the
(b) Slowly open the angle valve (charging valve)
reverse of removal procedure (1) above.
(36) and allow cylinder pressure to bleed off.
(c) After all pressure is relieved, use a wrench to
disconnect the metal tube assembly (1) flare nut at the
adapter (2) end.
2-3
|