5-614. The lamp enable signals that light the other
are involved with the individual indicators on the front
indicators on the front panel are described in paragraphs
panel.
5-146 through 5-153. No unusual or complicated circuits
SECTION VI
AC POWER DISTRIBUTION AND POWER SUPPLY ASSEMBLY FUNCTIONAL OPERATION
percent) dc voltages: +5 volts at 70 amperes full load,
5-615. INTRODUCTION.
+12volts at 4 amperes full load, and -12volts at 4
amperes full load. When the POWER CONTROL switch
5-616. This section contains a block diagram discussion
on the front panel is set to the ON position, the power
of the ac power distribution in the multiplexer set. This
supply energizes and produces the three regulated dc
discussion, in paragraphs 5-618 and 5-619, also includes
voltages.
The +5 volts lights POWER CONTROL
the input power circuit to the air cooling blower as part of
indicator DS6 on the front panel. When anyone of the
the ac power distribution function. Paragraphs 5-620
three dc voltages increases by more than 20 percent of
through 5-645 contain the block diagram discussion and
the rated outputs, the power supply is automatically shut
detailed circuit discussions for the power supply
down and all indicators on the front panel are out except
assembly (power supply).
POWER SUPPLY ALARMS indicator DS10 on the front
panel. When anyone of the three dc voltages decrease
by more than 20 percent, the POWER SUPPLY
ALARMS indicator on the front panel lights; the power
5-617. AC POWER DISTRIBUTION.
supply does not shut down. When the temperature in
the power supply exceeds 205F (960C), thermostat
5-618. The 115v ac power is applied through RFI filter
switch S1 in the power supply closes to generate signal
A6 on the rear panel (figure 5-45) to circuit breaker CB1
HOT- that energizes temperature alarm relay K2 on the
on the front panel. When POWER CONTROL switch S4
front panel.
When the relay is energized, the
is set to the ON position, the 115v ac is applied to the
TEMPERATURE ALARMS indicator lights, the inhibit
power supply and to EMI filters FL1, FL2.  Interlock
power supply signal IPSE is applied through the TEMP
switch S1 is closed when the blower panel is mounted in
SHUTDOWN jumper to shut down the power supply, and
place on the multiplexer set. When the blower panel is
overtemperature signals TEMPC1 and TEMPC2 provide
removed from the multiplexer set, S1 automatically
a closed-loop condition to the REMOTE ALARM
opens and removes the input power.  The EMI filters
connector on the rear panel. Temperature alarm relay
prevent any noise generated by the blower from reaching
K2 is a latch relay that remains in the energized state
the logic circuits in the multiplexer set. Run capacitor C1
until the POWER CONTROL switch is set to the OFF
provides the phase shift to energize the Wye wound
position and then back to the ON position. When the
motor in the blower.  Bleeder resistor R1 provides a
TEMP SHUTDOWN jumper is not installed, and an
discharge path for C1 when the blower panel is removed
overtemperature condition exists, the power supply
from the multiplexer set.
remains energized and the TEMPERATURE ALARMS
indicator lights.
5-619. The power supply provides three regulated (+1.0
Change 2 5-167