Page Title: Perform resistance checks of the generator per chart IV (Checks should be made at the pin side of the connector)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TB 9-2350-257-20-1
STEP 16
Disconnect harness 11655542 at the engine disconnect.
Perform resistance checks of the generator per chart IV
(Checks should be made at the pin side of the
connector.)
a. If generator checks per chart IV, repair harness
11655542.
b. If generator does not check per chart IV,
proceed to step 17.
CHART IV
Engine
Disconnect
Accessory
Connector
From ('+)
To (-)
Ohms
11655456
J (Circuit 1)
GROUND
1-3
11655456
L (Circuit 534)
GROUND
5-12
11655456
C (Circuit 533)
GROUND
12-15
11655456
GROUND
C (Circuit 533)
Infinite