Page Title: Maintenance of Ground Hop Filter.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TB 9-2300-378-14
(d) Insert one retainer into opposite holes in aluminum plate so that retainer will
hold filter assembly in place against plate.
(e) Install washer (MS27183-15) and wing nut on threaded ends of retainer. Place
o n e end of chain handle assembly and wing nut on other threaded end of
retainer.
(f) Repeat steps (d) and (e) to install second retainer.
( g ) Tighten wing nuts evenly until filter seal is uniformly compressed along
e n t i r e circumference.
(8) Installation of Ground Hop Filter.
NOTE
Prior to removal of air cleaner-to-turbosupercharger hose
a s s e m b l y , mark it with chalk or grease pencil.  This will
i n d e x the hose for easy installation and ensure proper
alinement.
(a) Remove air cleaner-to-turbosupercharger hose assembly from engine.
(b) Install filter on turbosupercharger elbow.
NOTE
Engine intake openings must be plugged or taped when
filter units are not attached.
(9) Maintenance of Ground Hop Filter.
C l e a n filter element as necessary. Never
( a ) Inspect filter unit prior to use.
ground hop using a dirty filter.
(b) Keep modified hose assembly on ground hop air filter plugged when unit is not
in use to prevent dirt from entering clean air inside of filter unit.
( c ) Remove unit when ground hopping operations are discontinued to prevent
filter from being exposed to elements.
(10) Stowage. Upon completion of ground operations, perform the following:
(a) Clean ground hop filter:
WARNING
Compressed air used for cleaning purposes must not exceed
90 psi.  Use only with effective chip guarding and personal
protective equipment (goggles/shield, gloves, etc.).
Direct compressed air (not to exceed 90psi) against inside of filter element.
1.
Place each filter in duffel bag with flat end facing duffel bag bottom.
2.
Place each air hose, with clamps into duffel bag on top filter. Close duffel
3.
bag using snap fastener.
4-25